 LABORATORY
DLM Series
3000-4000 WATTS PROGRAMMABLE DC SUPPLY Features
* * * * * * * High power density Preview push button Remote voltage sense & remote operation Calibration without removing covers Regulatory compliance Parrallel or series operation IEEE-488.2 and RS-232 interface options
Specifications
INPUT
Input Voltage 3KW:180-264VAC, single or three phase (<200VAC range limited to 40C maximum) 4KW:180264VAC, three phase (<200VAC range limited to 40C maximum) 47-63Hz for both single and three phase input 0.95 typical with three phase input 0.98 typical with single phase input
OPERATING
Efficiency 5-8V Models: 82% typical 16-80V Models: 87% typical 150-600V Models: 85% typical The maximum allowed sense line drop is 2V for 5V, 8V and 16V models and 5V for all other models Unit will not be damaged due to misconnection of the remote sense leads Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5VDC, 010VDC, or 0-5k Voltage or current can be monitored with userselectable ranges, 0-5VDC or 0-10VDC
Remote sense Remote sense protection Remote programming
Frequency Power Factor
ENVIRONMENTAL
Operating temperature 0C to 50 (No De-rating) Storage temperature Cooling -40C to 65C Internal fan with over-temperature protection
Remote monitoring
OUTPUT
Voltage adjustment Current adjustment Ripple & Noise Regulation (Line or Load) Transient response Zero to rated output Zero to rated output See table Voltage: 0.05% of maximum rated output +2mV Current: 0.1% of maximum rated output Typically recovers in 1ms to within 1% of steady-state output voltage (greater than 50% Vmax) for a 70100% or 100-70% load change +/-0.05% of maximum voltage or current over 8 hours after 15 minute warm-up time at fixed line, load and temperature
Over-voltage protection Crowbar type adjustable from 5-110% rated output using front panel control (local or remote program selectable) Displays and indicators Two 3.5 digital LED displays indicate output voltage, output current and over-voltage setting. LED indication for power on, shut-down, remote, overvoltage, overtemperature and front panel lockout, constant voltage and constant current modes. IEEE-488.2 indicators include error, SRQ and address Software Built-in protection Operational features LabVIEW(R) driver for M9E/M85 (Contact Powerbox) Over-voltage (resets by cycling the Enable/standby switch), over-temperature (will automatically reset) Master/slave parallel operation, up to 2 units can be connected in parallel with active current sharing control to within 10% of each supply. Series operation, up to 3 units of the same model type can be connected in series (consult manual). Negative terminal rated at 150Vmax Above ground CE Mark on all models
Stability
Temperature coefficient 0.02%/C of maximum output voltage 0.03%/C of maximum output current
Regulatory compliance
488
DLM Series
3000-4000 WATTS PROGRAMMABLE DC SUPPLY Selection Tables
OUTPUT RATING MODEL
DLM 5-350E DLM 5-450E DLM 8-350E DLM 8-450E DLM 16-185E DLM 16-250E DLM 32-95E DLM 32-125E DLM 40-75E DLM 40-100E DLM 60-50E DLM 60-66E DLM 80-37E DLM 80-50E DLM 150-20E DLM 150-26E DLM 300-10E DLM 300-13E DLM 600-5E DLM 600-6.6E
LABORATORY
VOLTAGE (VDC)
0-5 0-5 0-8 0-8 0-16 0-16 0-32 0-32 0-40 0-40 0-60 0-60 0-80 0-80 0-150 0-150 0-300 0-300 0-600 0-600 PREVIEW ACCURACY
REGULATION LINE AND LOAD METER ACCURACY VOLTAGE VOLTAGE CURRENT CURRENT CURRENT (0.05% OF VMAX (0.5% OF VMAX (0.75%OF IMAX (ADC) (0.1% OF IMAX) +2MV) +1 COUNT) +1 COUNT)
0-350 0-450 0-350 0-450 0-185 0-250 0-95 0-125 0-75 0-100 0-50 0-66 0-37 0-50 0-20 0-26 0-10 0-13 0-5 0-6.6 5mV 5mV 6mV 6mV 10mV 10mV 18mV 18mV 22mV 22mV 32mV 32mV 42mV 42mV 77mV 77mV 152mV 152mV 302mV 302mV RIPPLE AND NOISE RIPPLE (RMS)* 12mV 12mV 12mV 12mV 10mV 10mV 10mV 10mV 10mV 10mV 15mV 15mV 15mV 15mV 30mV 30mV 60mV 60mV 100mV NOISE (P-P) 100mV 100mV 100mV 100mV 100mV 100mV 100mV 100mV 100mV 100mV 100mV 100mV 120mV 120mV 200mV 200mV 300mV 300mV 500mV 500mV 350mA 450mA 350mA 450mA 185mA 250mA 95mA 125mA 75mA 100mA 50mA 66mA 37mA 50mA 20mA 26mA 10mA 13mA 5mA 7mA 0.04V 0.04V 0.05V 0.05V 0.09V 0.09V 0.3V 0.3V 0.3V 0.3V 0.4V 0.4V 0.5V 0.5V 0.9V 0.9V 1.6V 1.6V 3.1V 3.1V 4A 5A 4A 5A 3A 3A 0.8A 1A 0.7A 0.9A 0.5A 0.6A 0.4A 0.5A 0.3A 0.3A 0.09A 0.11A 0.05A 0.06A
MODEL
OVP VOLTAGE CURRENT ADJUSTMENT (0.5% OF (1.0% OF RANGE (5% VMAX +1 IMAX +1 TO 110% OF VMAX) COUNT) COUNT) 0.04V 0.04V 0.05V 0.05V 0.09V 0.09V 0.3V 0.3V 0.3V 0.3V 0.4V 0.4V 0.5V 0.5V 0.9V 0.9V 1.6V 1.6V 3.1V 5A 6A 5A 6A 3A 4A 1.1A 1.4A 0.9A 1.1A 0.6A 0.8A 0.5A 0.6A 0.3A 0.4A 0.11A 0.14A 0.06A 0.3-5.5V 0.3-5.5V 0.4-8.8V 0.4-8.8V 0.8-17.6V 0.8-17.6V 1.6-35V 1.6-35V 2-44V 2-44V 3-66V 3-66V 4-88V 4-88V 7.5-165V 7.5-165V 15-330V 15-330V 30-660V
MAXIMUM CURRENT TOTAL VOLTAGE CURRENT VOLTAGE (0.03%/ REMOTE (0.05% OF (0.05% (0.02%/C SENSE C OF VMAX) OFIMAX) OF VMAX) DROP IMAX) 3mV 3mV 4mV 4mV 8mV 8mV 16mV 16mV 20mV 20mV 30mV 30mV 40mV 40mV 75mV 75mV 150mV 150mV 300mV 300mV 175mA 225mA 175mA 225mA 93mA 125mA 48mA 63mA 38mA 50mA 25mA 33mA 19mA 25mA 10mA 13mA 5mA 6.5mA 2.5mA 3.3mA 1mV 1mV 1.6mV 1.6mV 3.2mV 3.2mV 6mV 6mV 8mV 8mV 12mV 12mV 16mV 16mV 30mV 30mV 60mV 60mV 120mV 120mV 105mA 135mA 105mA 135mA 55mA 75mA 30mA 38mA 23mA 30mA 15mA 19.8mA 12mA 15mA 6mA 7.8mA 3mA 3.9mA 1.5mA 2mA 2V 2V 2V 2V 2V 2V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V
STABILITY
TEMP. COEFF.
DLM 5-350E DLM 5-450E DLM 8-350E DLM 8-450E DLM 16-185E DLM 16-250E DLM 32-95E DLM 32-125E DLM 40-75E DLM 40-100E DLM 60-50E DLM 60-66E DLM 80-37E DLM 80-50E DLM 150-20E DLM 150-26E DLM 300-10E DLM 300-13E DLM 600-5E
DLM 600-6.6E 3.1V 0.08A 30-660V 100mV *RMS ripple typical from 20Hz to 300kHz Dimensions: 2RU or 88mm(H)x482mm(W)x508mm(D) ; Weight: 18.2kg
Your dependable power partner - www.powerbox.com.au
489
LABORATORY
DLM Series
3000-4000 WATTS PROGRAMMABLE DC SUPPLY
OPTIONS & ACCESSORIES INPUT VOLTAGE OPTIONS
M1 M2 M9E M13 M51A M85 400 VAC input (4 kW only) 480 VAC input (4 kW only 1 2 3 4 5 6 7 8 9 10 11 12 13
J3 PROGRAM AND SENSE
Remote Output Enable 14 Remote Shutdown Input (+), Pos or Neg true logic selection with S1 +5 VDC Auxillary Output 1 mACurrent Source for OVP Programming OVP Status Indicator Overtemperature Shutdown Indicator DC Voltage Monitor Output Remote/Local Voltage Control Select 1 mA Current Source for Voltage Programming 1 mA Current Source for Current Programming Remote/Local Current Control Select N/C N/C
REMOTE INTERFACE OPTIONS
IEEE-488.2 and RS 232 Interfaces Locking shafts (front panel potentiometers) Optically Isolated analog programming Multichannel Slave Interface
Remote Shutdown Return(-) 15 Remote OVP Programing Input 16 Remote Programming Indicator 17 Operating Mode Indicator Status Indicator Return (-) Current Monitor Output N/C Voltage Programing Input Current Programing Unit N/C Programming/Monitor Return N/C 18 19 20 21 22 23 24 25
PARALLEL CABLE
5361969-01 Paralleling Cable, one cable per slave unit
RACK SLIDE KIT
105-330-26 Rack slide kit
Technical Illustration
490


▲Up To Search▲   

 
Price & Availability of DLM40-100E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X